BMZGK - NESSLER REAGENT

  • MSDS: BMZGK
  • Manufacturer: HACH CO
  • Product Name: NESSLER REAGENT
  • National Stock Number: 6810-01-011-7192
Product Identification

Product ID:NESSLER REAGENT
MSDS Date:12/31/1996
FSC:6810
NIIN:01-011-7192
MSDS Number: BMZGK

Responsible Party
HACH CO
100 DAYTON RD
AMES, IA 50010
US

Emergency Phone: 515-232-2533, CHEMTREC 800-424-9300

Info Phone: 303-669-3050/800-227-4224

Cage: 4T252

Contractor
KAMPI COMPONENTS CO., INC.
721 BRISTOL, PA 19007-3517 US

Telephone: 215-736-2000

Cage: 7Z016

Ingredients

MERCURIC IODIDE

CAS: 7774-29-0

RTECS: OW5250000

Fraction By Weight: < 15%

OSHA PEL 0.1 MG/M3 (HG)

ACGIH TLV: 0.05 MG/M3 (HG)


SODIUM HYDROXIDE (CERCLA)

CAS: 1310-73-2

RTECS: WB4900000

Fraction By Weight: < 20%

OSHA PEL 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SODIUM IODIDE

CAS: 7681-82-5

RTECS: WB6475000

Fraction By Weight: < 10%


IODINE

CAS: 7553-56-2

RTECS: NN1575000

Fraction By Weight: < 1%

OSHA PEL C 0.1 PPM

ACGIH TLV: C 0.1 PPM; 9596


WATER, DEMINERALIZED

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: TO 100%

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE-MAY CAUSE BURNS TO SKIN AND EYES
ON CONTACT. VERY TOXIC TO CENTRAL NERVOUS SYSTEM IF INGESTED OR
ABSORBED THROUGH SKIN. CHRONIC- CUMULATIVE POISON. POSSIBLE KIDNEY
OR CNS DAMAGE.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INGESTION/ABSORBTION: EMOTIONAL INSTABILITY,
INSOMNIA, TREMORS IN HANDS, DEPRESSION, AND IRRATABILITY.
SKIN/EYES: BURNS, BLISTERS, REDNESS, RASH, TEARING, PAIN.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE ALLERGIES OR
SENSITIVITY TO MERCURY; EYE OR SKIN CONDITIONS; DISORDERS OF THE
CENTRAL NERVOUS SYSTEM OR KIDNEY.

First Aid

First Aid:EYE AND SKIN CONTACT:IMMEDIATELY FLUSH WITH WATER FOR 15
MINUTES.REMOVE CONTAMINATED CLOTHING.CALL PHYSICIAN.
INHALATION:REMOVE TO FRESH AIR.CALL PHYSICIAN.INGESTED:DO NOT
INDUCE VOMITING.IF CONSCIOUS , DRINK 1-2 GLASSES OF WATER.CALL A
PHYSICIAN IMMEDIATELY.

Fire Fighting

Extinguishing Media:NOT APPLICABLE. DLA-HMIS:MEDIA APPROPRIATE FOR
SURROUNDING FIRE.
Fire Fighting Procedures:DLA-HMIS: FIRE FIGHTERS SHOULD USE NIOSH
APPROVED SELF CONTAIED BREATHING APPARATUS & FULL PROTECTIVE
EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF TOXIC FUMES.

Accidental Release

Spill Release Procedures:DO NOT ALLOW THE MERCURY TO CONTAMINATE AIR OR
WATER. SOAK UP SOLUTION WITH INERT MATERIAL. DO NOT BREATHE FUMES.
DECONTAMINATE AREA WITH MERCURY ABSORBING COMPOUNDS AVAILABLE
COMMERCIALLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINERS.
Other Precautions:WASH THOROUGHLY AFTER HANDLING. AVOID CONTACT WITH
EYES, SKIN AND CLOTHING. DO NOT BREATHE FUMES OR VAPORS.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR OR
AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29 CFR
1910.134.
Ventilation:USE LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS.
Protective Gloves:RUBBER GLOVES
Eye Protection:SAFETY GOGGLES WITH OPTIONAL FACE SHIELD
Other Protective Equipment:EYE WASH STATION, SAFETY SHOWER, FUME HOOD,
LAB GRADE GOGGLES, DISPOSABLE GLOVES, LAB COAT.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
FORMULATION CHANGED. FOR PREVIOUS FORMULATION, SEE P/N A, SAME NSN.

Chemical Properties

HCC:B1
Boiling Pt:B.P. Text:230F,110C
Spec Gravity:1.265
pH:12.1
Solubility in Water:APPRECIABLE
Appearance and Odor:CLEAR, LIGHT YELLOW LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, ORGANICS, AMMONIA, ALDEHYDES
Stability Condition to Avoid:EXTREME TEMPERATURES AND LIGHT
Hazardous Decomposition Products:TOXIC FUMES OF MERCURY, IODINE AND
IODINE COMPOUNDS

Disposal

Waste Disposal Methods:DISPOSE OF ALL MERCURY CONTAMINATED MATERIAL IN
AN EPA APPROVED HAZARDOUS WASTE FACILITY. DISPOSAL SHOULD BE MADE
IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL
ENVIRONMENTAL REGULATIONS. EPA/RCRA HAZWASTE NUMBER D009
(MERCURY)MAY APPLY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.